RT Fuse Block 6 Circuit w/Ground, Bulk Pack

21.25 21.25 USD

28.50

Option not available

Add to Cart


        OEM / Distributor volume pricing available - learn more
        All products ship in 1 to 3 business days.


        LED FUSE DIAGNOSTICS

        Blown fuse LED indication for each output circuit provides clear indication of faulty circuits and eases trouble-shooting issues remotely.


        SPARE FUSE LOCATIONS

        Two locations for spare fuses or test resistors for reducing siren volumes during evaluation.

         

                                                                ground block included

        Includes 12 position ground return block with multi-level low amp terminal screws for improved routing 


        STAINLESS STEEL SELF-LOCKING HARDWARE

        100% Non-ferrous corrosion resistant materials. All attachment screws and nuts are self-locking.



         


        ground block separates

        Ground Block section optionally separates from Fuse Block section affording increased deployment options for challenging installations

         


        COVER / LABEL RECESSES

        Protective cover for fuses and output terminals includes label recesses. Standard and custom label sets also available.

         

        PRIMARY SPECIFICATIONS

         

        MAXIMUM CURRENT - ENTIRE BLOCK

        100 Amps DC

        MAXIMUM CURRENT - PER CIRCUIT

        30 Amps DC

        OPERATING VOLTAGE

        12 or 24 V Systems,  0 to 36 Vdc 

        MAXIMUM OUTPUT WIRE SIZE

        #10 AWG

        NUMBER OF ground bus POSITIONS

        Twelve (12)


        COMPATIBLE FUSE TYPES

        ATO / ATC / ATF

        MAXIMUM FUSE VALUE

        40 Amps DC

        OUTPUT TERMINAL CONNECTION

        Ring Terminals / M4 (#8)

        NUMBER OF FUSE POSITIONS

        Six (6)

        Application Example - 12 Position RT Fuse Block, RT Ground Block, and TDR Relay

        A well installed power distribution and clean ground return solution. Fused vehicle power is connected to the TDR Time Delay Relay (upper right), then distributed to the 12 Position RT Fuse Block (left). The RT Ground Block (lower right) was separate from the Fuse Block where it was originally tied together, and re-located to a more convenient locations for effective wire harness routing. Also shown, optional cover labels from emergency vehicle label sheet set.

        Odoo • Text and Image
                         

        downloads

         

        RT Fuse Block Sales Sheet

         

         

         

         

         

         

        Screw Terminal Fuse Block 6 Circuit w/Cover and Negative Bus, Includes Blown Fuse LED Indication...